Basic Info.
Model NO.
MC
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Yuchai Engine
Alternator Brand
Stamford/Marathon/Mecca and Unique Brand for Usage
Control Panel
Deepsea/Comap/Datakom/Delixi/Smartgen and Others
Phase
Single Phase/Three Phase
Canopy Type
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz or Adjusted Frequency Via Converter
Voltage Output
230/400V, Others as Application Requested
Application
Telecom Communication/Hospital/ Construction
Transport
Plywood/Plastic Packing
Super Silent Generator
Portable Generator
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Generator Set
20FT Container/40FT Container
ATS
as Application Requested
Certificate Available
CE, ISO, OEM Authorization etc.
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
Electrical
Trademark
Mecca
Origin
China
HS Code
85021100
Production Capacity
1000/Year
Product Description
100KVA Silent Type Diesel Power Generator Set with YUCHAI Engine
-With removable trailer(2 wheels,4 wheels)
-With Stamford / Leroy Somer / Marathon alternator
-With ABB MCCB & Electronic Components
-Electric start with battery
-10 hours Lasting Base Integrated fuel Tank
-Strictly comply with ISO9001/CE
-Option:ATS, Deepsea / ComAp controller
General Feature | ||||||||||||||||||
♦ Assembled by diesel engine and Brushless alternator. | ||||||||||||||||||
Three filters as standard, fuel and water separator as optional. | ||||||||||||||||||
♦ Radiator and fan with safety guard. | ||||||||||||||||||
♦ Single bearing alternator IP 23, Insulation Class H. | ||||||||||||||||||
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank. | ||||||||||||||||||
♦ Automatic control panel and 3 poles circuit breaker, internal cable. | ||||||||||||||||||
♦ 12V or 24V battery, battery wires. | ||||||||||||||||||
♦ Battery and float battery charger as standard supply scope. | ||||||||||||||||||
♦ Fuel level indicator in meter and panel | ||||||||||||||||||
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. |
COMPANY PROFILE
Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.
As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Perkins, Deutz, Man, Doosan, Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc.
Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, military, etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.
With over 10 years of experience in manufacturing and exporting energy products, the Mecca team will provide you full-service solutions. BELIVE THAT WE ARE WORTHY OF YOUR TRUST!
As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Perkins, Deutz, Man, Doosan, Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc.
Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, military, etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.
With over 10 years of experience in manufacturing and exporting energy products, the Mecca team will provide you full-service solutions. BELIVE THAT WE ARE WORTHY OF YOUR TRUST!
-----------------------------------------------------------------------------------------------MAINTENANCE---------------------------------------------------------------------------------------------
General Troubleshooting
This section lists the generating set for some common fault, the reasons for the failure and determines the
method of fault. General operators can determine their own fault and note, maintenance it according to the
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.
Please remember the following suggestions before repairing:
- Make sure that study the failure carefully before any operation.
- Repair with the easiest way and most commonly used method.
- Find the exact causes of failure and completely solve the fault.
1. Generator Sets
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.
(Some models of control panel installed only parts of the following warning indicator light)
Icon | Indicator Light | Reason | Fault Analysis |
Low oil pressure alarm | Low oil pressure alarm | When oil pressure does not reduce normally, the light is on. | -General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. |
High water temperature alarm | High water temperature alarm | When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. | -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Low fuel level alarm | Low fuel level alarm | When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. | -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Battery charger fault alarm | Battery charger fault alarm | If the charging system has fault, when engine running, the light is off. | -Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. |
Crank failure alarm | Crank failure alarm | When the generator set failed three times (or six times) in a row starting, the light is on. | -Oil supply system or re-start the system failure caused. |
Overload or breaker tripping alarm | Overload or breaker tripping alarm | When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. | -In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. |