Basic Info.
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Transport Package
Wooden Box
Trademark
weifang
Origin
China
Production Capacity
5000units/Years
Product Description
Model parameters
TECHNICAL PARAMETER | ||||||||||
Weifang Series | ||||||||||
Generator Method | Rated power | standby power | displacement (L) | cylinder no | cylinder diameter (mm) | stroke(mm) | fuel consumpation (g/kw-h) | size (LWH) | ||
KW | KVA | KW | KVA | |||||||
BC-30GF | 30 | 38 | 33 | 41 | 3.61 | 4 | 100 | 92 | 258.4 | 1815x600x1200 |
BC-40GF | 40 | 50 | 42 | 53 | / | 4 | 100 | 92 | 258.4 | 1920x720x1250 |
BC-50GF | 56 | 70 | 62 | 78 | 4.5 | 4 | 105 | 92 | 231 | 2150x690x1250 |
BC-75GF | 84 | 105 | 92 | 115 | 6.5 | 6 | 105 | 92 | 231 | 2300x690x1300 |
BC-100GF | 110 | 138 | 121 | 151 | 7 | 6 | 105 | 118 | 224 | 2400x690x1360 |
BC-120GF | 132 | 165 | 145 | 181 | 7 | 6 | 105 | 130 | 224 | 2570x760x1400 |
BC-150GF | 165 | 206 | 180 | 225 | 8 | 6 | 105 | 118 | 208 | 2715x800x1440 |
BC-200GF | 235 | 294 | 258 | 323 | 9.8 | 6 | 126 | 130 | 220 | 2950x890x1480 |
BC-230GF | 258 | 323 | 283 | 354 | 9.8 | 6 | 126 | 130 | 220 | 2935x980x1490 |
BC-250GF | 286 | 358 | 315 | 394 | 9.8 | 6 | 126 | 130 | 220 | 2987x950x1490 |
BC-300GF | 320 | 400 | 352 | 440 | 11.6 | 6 | 126 | 130 | 205 | 2987x950x1627 |
BC-300GF | 320 | 400 | 352 | 440 | 11.6 | 6 | 126 | 130 | 205 | 3050x950x1520 |
BC-330GF | 368 | 460 | 405 | 506 | 12.6 | 6 | 127 | 130 | 212 | 3050x950x1520 |
BC-360GF | 400 | 500 | 440 | 550 | 12.6 | 6 | 127 | 130 | 212 | 3135x1100x1620 |
1. Noted: Output voltage: 400V/230V Rated Power: 50Hz Rotute speed: 1500r/min Rated Power factor: 0.8lag Insuationl class: H
2. Environment Condition: 1500 meters altitude, 40 ºC temperature.
KW Weifang Genset Technical Parameters | |||||
Generator Model | BC-20GF/-150GF | Output Power | 20KW-150KW | Steady state Frequency Regulation | ≤±1% |
Rated Voltage | 400/230V | Stable Voltage Regulation | ≤±1% | Transient Frquency Regulation | ≤±10% |
Rated Current | 36A-1800A | Transient Voltage regulation | ≤±15% | Frequency Stabilization Time | ≤3S |
Rated Frequency | 50HZ | Voltage Setting Time | ≤1S | Frequency Fluctuation | ≤±0.5% |
Weight | 630KG-1530KG | Voltage Fluctuation | ≤±0.5% | Size | customized |
Text power | 25kva-187.5kva | Rated Speed | 1500RPM | Noise | 95dB(A) |
Diesel Parameters | |||||
Generator Model | Rated Power | 20KW-150KW | Overload Power | 22KW-165KW | |
Cylinders No | Four/Six /Cylinders | Speed | 1500RPM | Starting Model | DC24V Electricity |
Type | Four Stroke | Intake Type | Normally Aspirated /Turbo charge | Fuel Consumption(g/kw.h) | ≤236-238 |
Coling Method | Closed Cooling Water | Lubrication Method | Combined pressure and splash | Cylinder Diameter/Distance of travel | 100/115mm 113/115mm |
Fuel Feeding Method | direct injection | Speed Regulation | Mechanical Speed Governors | Engine displacement | 3.6L |
Fuel Type/Fuel Class | China 0#(Light diesel oil) | Compression Rate | 19:01 | Manufacturer | Weifang |
Generator Parameters | |||||
Generator Model | Rated Voltage | 400V/230V | |||
Type | All the copper Brushless | Electrical Made | Three-phase four-wire,neutral ground | ||
Model | Steady state Frequency Regulation | ≤±1% | |||
Frequency | 50Hz | Short circuit protection | Air Switch | ||
Insulation Class | H | Short-time Current | 150% 2min | ||
Protection Level | IP23 | Overload Capacity | Overload 10% one hour |
Specification Characteristic
1. The unit performance is reiable and stable
2. Low oil consumption , low emissions, low noise
3. The diesel generator set adopt rotary diesel,oil filter and dry oil filter
4.the unit wear resistance and durability, compact structure, easy to operate
Product Pictures
Packing and Logistics
FAQ
Q1: Do you offer guarantee for the products?
A: Yes, we offer 12 month years warranty to our products.
Q2: How to select a suitable generator set?
A: According to the actual electricity consumption, plant area to evaluate the required power and number of generator sets, we will recommend the most suitable generator set configuration for you.
Q3. May you print my logo on diesel generator sets product?
A: Yes. Please inform us formally before our production and confirm the design firstly based on .
Q4. How to proceed an order for diesel generator set?
A: Firstly let us know your requirements or application.
Secondly We provide solution according to your need.
Thirdly customer confirms the detail specs of the order, and arrange pay the deposit.
Fourthly We arrange the production after payment received.
Q5. How do you ship the goods and how long does it take to arrive?
A: Normally by sea shipping .Shipping time depends on distance.
Q6: How to deal with the faulty?
A: during the guarantee period, if some spare parts broken not from human behavior, we can send you related spare parts.or you can choose to order some parts together from generator sets. we can support online technique support all the time. if you have some technique problem on genset running, we can support professional technique staff go to your place to guide you work it out.