Solar Charge Generators for Drinking Water and House Load

Customization: Available
Output Type: AC Single Phase
System: Off-Grid system

Products Details

Basic Info.

Model NO.
SMSH-40KW
Power
40kw
Standard
Standard
Max. DC Input Voltage
1000V
Rated AC Output Power
18kw
System Capacity
5kw
Output Frequency
50Hz/60Hz
MPPT Voltage Range
300-1000V
Max. Efficiency
98%
Controller
MPPT
Battery Type
Free Maintenance Gel Battery
Solar Power Generator Technology
Ipm or IGBT of Mitsubishi
Battery
12V/200ah X 24PCS
Solar Power Generator Battery
Maintenance-Free Lead-Acid Battery
Special Design
Accept
Waveform
Thd<2%
Connector
Mc4
Junction Box
TUV Standard
Transport Package
Carton or Wood Boxes
Specification
CE RoHS
Trademark
SUNMASTER
Origin
Zhejiang
HS Code
8502390000
Production Capacity
50, 000 PCS/Year

Product Description


Solar Charge Generators for Drinking Water and House Load
Connecting Diagram
Solar Charge Generators for Drinking Water and House Load
 
Configuration List

Solar Charge Generators for Drinking Water and House Load
Item Certification Description Q'ty Warranty
Solar panel TUV / IEC / EC Mono or Poly 2 pcs 20 years
Inverter CGC / CQC / VDE One (MPPT) tracking/ 50/60Hz; 230Vac 1500W/ SM-SH1500W 1 set 5 years
Distribution box
(Optional)
CE Lighting Protection. Air switch,Fusegar, knifeswitch, 1 set 5 years
Mounting system CE Slant roof bracket/ Cement Ground bracket/ Soil ground bracket 1set 10 years
PV cable TUV/ UL DC port PV1-F 1*4mm² 20m 10 years
AC port YJV-3*6mm² 10m 10 years

Solar Charge Generators for Drinking Water and House Load
 
Solar Panel
Solar Charge Generators for Drinking Water and House Load
Type MONO POLY
Power class 280W 335W 270W 320W
Open Circuit Voltage (Voc) 43 44 43 43.8
Short Circuit Voltage (Isc) 8.35 9.92 8.23 9.42
Max power Voltage (Vmp) 36 36 36 36.5
Max Power Current (Imp) 7.78 9.3 7.35 8.76
Efficiency ≥17.1% ≥17.2% ≥16.5% ≥16.4%
Dimension (mm) 1650x991x35 1960x991x35 1650x991x35 1960x991x35
Weight (kg) 18±5% 22.5±5% 18±5% 22.5±5%
 
Solar Inverter
Solar Charge Generators for Drinking Water and House Load
Ambient temperature range -25~+60ºC(>45ºC deloading)
Relative humidity 0~95%
Max operating altitude 4000m (>3000m derating)
Protection degree IP65
Topology Transformerless
Night power consumption (W) <1
Cooiong method Natural convection
Noise emision (dB) <25
Display LCD
Warranty (Year) 5/10/15/20/25 (Optional) Years
 
Solar Controller
Solar Charge Generators for Drinking Water and House Load
Rated Charge current(A) 40A
Rated DC voltage(V) 24/48 automatic identification
Solar input  Max voltage(V) 42/84
Battery Over charge protective voltage(V) 28.6/57.2
Battery Over charge recover voltage(V) 27.4/54.8
Battery Constant charge voltage(V) 27/54
Battery Over discharge alarm voltage(V) 20/40
Environment Humidity  and temperature 0-90%  No condense,55ºC
Protective Functions Protection against anti-charge at night,battery over charge, over discharge protection,Joint-reversed of solar modules
 
Solar Battery

Solar Charge Generators for Drinking Water and House Load
Nominal Voltage 12V
Nominal Capacity 100Ah(10hr,1.80V/cell,25ºC)
Approximate Weight 27.5 kg
Internal Resistance 5.5  mΩ(Lead terminal)
Terminal Lead wire(4.0mm²×1.8m)
Maximum Charge Current 25 A
Ambient Temperature -35~55 ºC
Dimension Length 329mm(±2 mm)
Width 172mm(±2 mm)
Container Height 214mm(±2 mm)
Total Height 236mm(±2 mm)
Case ABS
 
PV Combiner Box
Solar Charge Generators for Drinking Water and House Load
Components Parameter Function
Circuit breaker (Air switch) 40A When the current of the protected,circuit exceeds the specified value,the circuit breaker will automatically break off to protect the whole circuit.
Fusegear 40A When the current of the protected circuit exceeds the specified value,fusegear will break off automatically
Surge protective device (SPD) UC:420V lmax:20KA
In: 10KAUp1.8KV
Photovoltaic lightning protection device
One phase self dual over voltage protection device Working range 220V,50Hz,
over voltage protection
Uvo=270V±5V
Under voltage protection
Uoe= 170±5V
When the circuit voltage is highet or lower, it will shut down automatically.when the voltage reaches standard level, it will recover automatically.
Knife switch / automatic/ by hand

Solar Charge Generators for Drinking Water and House Load
Conductor
Tinned Fine Re Copper Strand, according to VDE0295/IEC60228. Class 5
Insulation
Polyolefin Copolymer electron-beam coss-linked
Sheath Jacket
Polyolefin Copolymer electron-beam coss-linked
Nominal Voltage
Uo/U=600V/1000VAC, 1000V/1800VDC
Test  Voltage
6500V, 50Hz, 5Min
Temperature Rating
-40°C-125°C ,More than 25 Years  (TUV)
Fire Performance
IEC 60332-1
Smoke Emission
IEC61034, EN 50286-2
Low Fire Load
DIN 51 900
Certification
TUV 2PFG 1169/08 2007 PV1--F
 
Mounging System
Solar Charge Generators for Drinking Water and House Load

The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can reach 70kg/ square eters

The whole system has strong safety performance.

Can be customized based on customer's cactual situation

The mounting system can be desingned with best solution based on slope roof, flat ground and soil ground


Solar Charge Generators for Drinking Water and House Load
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours